    CellCLI是Exadata上存储节点的一个命令,是管理和监控存储节点的一个重要接口。例如,可以通过它收集各种指标(metric)和警报(alert)。了解这些指标的一个好方法是通过CELLCLI命令,从中挖掘出最新的信息。

    可以通过以下命令得到存储节点所支持的所有指标:

    list METRICDEFINITION attributes objectType,metricType,Name,UNIT,description

    稍做整理,可以得到下面的表格:

objectType metricType Name UNIT description
CELL Instantaneous CL_BBU_CHARGE % Disk Controller Battery Charge
CELL Instantaneous CL_BBU_TEMP C Disk Controller Battery Temperature
CELL Instantaneous CL_CPUT % Percentage of time over the previous minute that the system CPUs were not idle.
CELL Instantaneous CL_CPUT_CS % Percentage of CPU time used by CELLSRV
CELL Instantaneous CL_CPUT_MS % Percentage of CPU time used by MS
CELL Instantaneous CL_FANS Number Number of working fans on the cell
CELL Instantaneous CL_MEMUT % Percentage of total physical memory on the cell that is currently used
CELL Instantaneous CL_MEMUT_CS % Percentage of physical memory used by CELLSRV
CELL Instantaneous CL_MEMUT_MS % Percentage of physical memory used by MS
CELL Instantaneous CL_RUNQ Number Average number (over the preceding minute) of processes in the Linux run queue marked running or uninterruptible (from /proc/loadavg).
CELL Instantaneous CL_SWAP_IN_BY_SEC KB/sec Amount of swap pages read in KB per second
CELL Instantaneous CL_SWAP_OUT_BY_SEC KB/sec Amount of swap pages written in KB per second
CELL Instantaneous CL_SWAP_USAGE % Percentage of swap used
CELL Instantaneous CL_TEMP C Temperature (Celsius) of the server, provided by the BMC
CELL Instantaneous CL_VIRTMEM_CS MB Amount of virtual memory used by CELLSRV in MB
CELL Instantaneous CL_VIRTMEM_MS MB Amount of virtual memory used by MS in MB
CELL Instantaneous IORM_MODE Number I/O Resource Manager objective for the cell
CELL Instantaneous N_NIC_NW Number Number of inactive network interfaces
CELL Rate N_HCA_MB_RCV_SEC MB/sec Number of megabytes received by InfiniBand interfaces per second
CELL Rate N_HCA_MB_TRANS_SEC MB/sec Number of megabytes transmitted by InfiniBand interfaces per second
CELL Rate N_NIC_KB_RCV_SEC KB/sec Number of kilobytes received by Ethernet interfaces per second
CELL Rate N_NIC_KB_TRANS_SEC KB/sec Number of kilobytes transmitted by Ethernet interfaces per second
CELL_FILESYSTEM Instantaneous CL_FSUT % Percentage of total space on this file system that is currently used
CELLDISK Cumulative CD_IO_BY_R_LG MB Number of megabytes read in large blocks from a cell disk
CELLDISK Cumulative CD_IO_BY_R_SM MB Number of megabytes read in small blocks from a cell disk
CELLDISK Cumulative CD_IO_BY_W_LG MB Number of megabytes written in large blocks to a cell disk
CELLDISK Cumulative CD_IO_BY_W_SM MB Number of megabytes written in small blocks to a cell disk
CELLDISK Cumulative CD_IO_ERRS Number Number of IO errors on a cell disk
CELLDISK Cumulative CD_IO_RQ_R_LG IO requests Number of requests to read large blocks from a cell disk
CELLDISK Cumulative CD_IO_RQ_R_SM IO requests Number of requests to read small blocks from a cell disk
CELLDISK Cumulative CD_IO_RQ_W_LG IO requests Number of requests to write large blocks to a cell disk
CELLDISK Cumulative CD_IO_RQ_W_SM IO requests Number of requests to write small blocks to a cell disk
CELLDISK Cumulative CD_IO_TM_R_LG us Cumulative latency of reading large blocks from a cell disk
CELLDISK Cumulative CD_IO_TM_R_SM us Cumulative latency of reading small blocks from a cell disk
CELLDISK Cumulative CD_IO_TM_W_LG us Cumulative latency of writing large blocks to a cell disk
CELLDISK Cumulative CD_IO_TM_W_SM us Cumulative latency of writing small blocks to a cell disk
CELLDISK Instantaneous CD_IO_LOAD Number Average I/O load for the cell disk
CELLDISK Instantaneous CD_IO_ST_RQ us/request Average service time per request for small IO requests to a cell disk
CELLDISK Rate CD_IO_BY_R_LG_SEC MB/sec Number of megabytes read in large blocks per second from a cell disk
CELLDISK Rate CD_IO_BY_R_SM_SEC MB/sec Number of megabytes read in small blocks per second from a cell disk
CELLDISK Rate CD_IO_BY_W_LG_SEC MB/sec Number of megabytes written in large blocks per second to a cell disk
CELLDISK Rate CD_IO_BY_W_SM_SEC MB/sec Number of megabytes written in small blocks per second to a cell disk
CELLDISK Rate CD_IO_ERRS_MIN /min Number of IO errors on a cell disk per minute
CELLDISK Rate CD_IO_RQ_R_LG_SEC IO/sec Number of requests to read large blocks per second from a cell disk
CELLDISK Rate CD_IO_RQ_R_SM_SEC IO/sec Number of requests to read small blocks per second from a cell disk
CELLDISK Rate CD_IO_RQ_W_LG_SEC IO/sec Number of requests to write large blocks per second to a cell disk
CELLDISK Rate CD_IO_RQ_W_SM_SEC IO/sec Number of requests to write small blocks per second to a cell disk
CELLDISK Rate CD_IO_TM_R_LG_RQ us/request Average latency of reading large blocks per request to a cell disk
CELLDISK Rate CD_IO_TM_R_SM_RQ us/request Average latency of reading small blocks per request from a cell disk
CELLDISK Rate CD_IO_TM_W_LG_RQ us/request Average latency of writing large blocks per request to a cell disk
CELLDISK Rate CD_IO_TM_W_SM_RQ us/request Average latency of writing small blocks per request to a cell disk
FLASHCACHE Cumulative FC_BYKEEP_OVERWR MB Number of megabytes pushed out of the FlashCache because of space limit for ‘keep’ objects
FLASHCACHE Cumulative FC_IO_BY_R MB Number of megabytes read from FlashCache
FLASHCACHE Cumulative FC_IO_BY_R_MISS MB Number of megabytes read from disks because not all requested data was in FlashCache
FLASHCACHE Cumulative FC_IO_BY_R_SKIP MB Number of megabytes read from disks for IO requests with a hint to bypass FlashCache
FLASHCACHE Cumulative FC_IO_BY_W MB Number of megabytes written to FlashCache
FLASHCACHE Cumulative FC_IO_BYKEEP_R MB Number of megabytes read from FlashCache for ‘keep’ objects
FLASHCACHE Cumulative FC_IO_BYKEEP_W MB Number of megabytes written to FlashCache for ‘keep’ objects
FLASHCACHE Cumulative FC_IO_ERRS Number Number of IO errors on FlashCache
FLASHCACHE Cumulative FC_IO_RQ_R IO requests Number of read IO requests satisfied from FlashCache
FLASHCACHE Cumulative FC_IO_RQ_R_MISS IO requests Number of read IO requests which did not find all data in FlashCache
FLASHCACHE Cumulative FC_IO_RQ_R_SKIP IO requests Number of read IO requests with a hint to bypass FlashCache
FLASHCACHE Cumulative FC_IO_RQ_W IO requests Number of IO requests which resulted in FlashCache being populated with data
FLASHCACHE Cumulative FC_IO_RQKEEP_R IO requests Number of read IO requests for ‘keep’ objects satisfied from FlashCache
FLASHCACHE Cumulative FC_IO_RQKEEP_R_MISS IO requests Number of read IO requests for ‘keep’ objects which did not find all data in FlashCache
FLASHCACHE Cumulative FC_IO_RQKEEP_R_SKIP IO requests Number of read IO requests for ‘keep’ objects with a hint to bypass FlashCache
FLASHCACHE Cumulative FC_IO_RQKEEP_W IO requests Number of IO requests for ‘keep’ objects which resulted in FlashCache being populated with data
FLASHCACHE Instantaneous FC_BY_USED MB Number of megabytes used on FlashCache
FLASHCACHE Instantaneous FC_BYKEEP_USED MB Number of megabytes used for ‘keep’ objects on FlashCache
FLASHCACHE Rate FC_BYKEEP_OVERWR_SEC MB/sec Number of megabytes per second pushed out of the FlashCache because of space limit for ‘keep’ objects
FLASHCACHE Rate FC_IO_BY_R_MISS_SEC MB/sec Number of megabytes read from disks per second because not all requested data was in FlashCache
FLASHCACHE Rate FC_IO_BY_R_SEC MB/sec Number of megabytes read per second from FlashCache
FLASHCACHE Rate FC_IO_BY_R_SKIP_SEC MB/sec Number of megabytes read from disks per second for IO requests with a hint to bypass FlashCache
FLASHCACHE Rate FC_IO_BY_W_SEC MB/sec Number of megabytes per second written to FlashCache
FLASHCACHE Rate FC_IO_BYKEEP_R_SEC MB/sec Number of megabytes read per second from FlashCache for ‘keep’ objects
FLASHCACHE Rate FC_IO_BYKEEP_W_SEC MB/sec Number of megabytes per second written to FlashCache for ‘keep’ objects
FLASHCACHE Rate FC_IO_RQ_R_MISS_SEC IO/sec Number of read IO requests per second which did not find all data in FlashCache
FLASHCACHE Rate FC_IO_RQ_R_SEC IO/sec Number of read IO requests satisfied per second from FlashCache
FLASHCACHE Rate FC_IO_RQ_R_SKIP_SEC IO/sec Number of read IO requests per second with a hint to bypass FlashCache
FLASHCACHE Rate FC_IO_RQ_W_SEC IO/sec Number of IO requests per second which resulted in FlashCache being populated with data
FLASHCACHE Rate FC_IO_RQKEEP_R_MISS_SEC IO/sec Number of read IO requests per second for ‘keep’ objects which did not find all data in FlashCache
FLASHCACHE Rate FC_IO_RQKEEP_R_SEC IO/sec Number of read IO requests for ‘keep’ objects per second satisfied from FlashCache
FLASHCACHE Rate FC_IO_RQKEEP_R_SKIP_SEC IO/sec Number of read IO requests per second for ‘keep’ objects with a hint to bypass FlashCache
FLASHCACHE Rate FC_IO_RQKEEP_W_SEC IO/sec Number of IO requests per second for ‘keep’ objects which resulted in FlashCache being populated with data
FLASHLOG Cumulative FL_ACTUAL_OUTLIERS IO requests The number of times redo writes to flash and disk both exceeded the outlier threshold
FLASHLOG Cumulative FL_DISK_FIRST IO requests The number of times redo writes first completed to disk
FLASHLOG Cumulative FL_DISK_IO_ERRS IO requests The number of disk I/O errors encountered by Smart Flash Logging
FLASHLOG Cumulative FL_EFFICIENCY_PERCENTAGE % The efficiency of Smart Flash Logging expressed as a percentage
FLASHLOG Cumulative FL_FLASH_FIRST IO requests The number of times redo writes first completed to flash
FLASHLOG Cumulative FL_FLASH_IO_ERRS IO requests The number of flash I/O errors encountered by Smart Flash Logging
FLASHLOG Cumulative FL_FLASH_ONLY_OUTLIERS IO requests The number of times redo writes to flash exceeded the outlier threshold
FLASHLOG Cumulative FL_IO_DB_BY_W MB The number of MB written to hard disk by Smart Flash Logging
FLASHLOG Cumulative FL_IO_FL_BY_W MB The number of MB written to flash by Smart Flash Logging
FLASHLOG Cumulative FL_IO_W IO requests The number of writes serviced by Smart Flash Logging
FLASHLOG Cumulative FL_IO_W_SKIP_BUSY IO requests The number of redo writes that could not be serviced by Smart Flash Logging because too much data had not yet been written to disk
FLASHLOG Cumulative FL_IO_W_SKIP_LARGE IO requests The number of large redo writes that could not be serviced by Smart Flash Logging because the size of the data was larger than the amount of available space on any flash disk
FLASHLOG Cumulative FL_PREVENTED_OUTLIERS IO requests The number of times redo writes to disk exceeded the outlier threshold; these would have been outliers had it not been for Smart Flash Logging
FLASHLOG Instantaneous FL_BY_KEEP Number The amount of redo data saved on flash due to disk I/O errors
FLASHLOG Instantaneous FL_EFFICIENCY_PERCENTAGE_HOUR % The efficiency of Smart Flash Logging over the last hour expressed as a percentage
FLASHLOG Instantaneous FL_IO_DB_BY_W_SEC MB/sec The rate which is the number of MB per second written to hard disk by Smart Flash Logging
FLASHLOG Instantaneous FL_IO_FL_BY_W_SEC MB/sec The rate which is the number of MB per second written to flash by Smart Flash Logging
FLASHLOG Instantaneous FL_IO_W_SKIP_BUSY_MIN IO/sec The number of redo writes during the last minute that could not be serviced by Smart Flash Logging because too much data had not yet been written to disk
GRIDDISK Cumulative GD_IO_BY_R_LG MB Number of megabytes read in large blocks from a grid disk
GRIDDISK Cumulative GD_IO_BY_R_SM MB Number of megabytes read in small blocks from a grid disk
GRIDDISK Cumulative GD_IO_BY_W_LG MB Number of megabytes written in large blocks to a grid disk
GRIDDISK Cumulative GD_IO_BY_W_SM MB Number of megabytes written in small blocks to a grid disk
GRIDDISK Cumulative GD_IO_ERRS Number Number of IO errors on a grid disk
GRIDDISK Cumulative GD_IO_RQ_R_LG IO requests Number of requests to read large blocks from a grid disk
GRIDDISK Cumulative GD_IO_RQ_R_SM IO requests Number of requests to read small blocks from a grid disk
GRIDDISK Cumulative GD_IO_RQ_W_LG IO requests Number of requests to write large blocks to a grid disk
GRIDDISK Cumulative GD_IO_RQ_W_SM IO requests Number of requests to write small blocks to a grid disk
GRIDDISK Rate GD_IO_BY_R_LG_SEC MB/sec Number of megabytes read in large blocks per second from a grid disk
GRIDDISK Rate GD_IO_BY_R_SM_SEC MB/sec Number of megabytes read in small blocks per second from a grid disk
GRIDDISK Rate GD_IO_BY_W_LG_SEC MB/sec Number of megabytes written in large blocks per second to a grid disk
GRIDDISK Rate GD_IO_BY_W_SM_SEC MB/sec Number of megabytes written in small blocks per second to a grid disk
GRIDDISK Rate GD_IO_ERRS_MIN /min Number of IO errors on a grid disk per minute
GRIDDISK Rate GD_IO_RQ_R_LG_SEC IO/sec Number of requests to read large blocks per second from a grid disk
GRIDDISK Rate GD_IO_RQ_R_SM_SEC IO/sec Number of requests to read small blocks per second from a grid disk
GRIDDISK Rate GD_IO_RQ_W_LG_SEC IO/sec Number of requests to write large blocks per second to a grid disk
GRIDDISK Rate GD_IO_RQ_W_SM_SEC IO/sec Number of requests to write small blocks per second to a grid disk
HOST_INTERCONNECT Cumulative N_MB_DROP MB Number of megabytes droped during transmission to a particular host
HOST_INTERCONNECT Cumulative N_MB_RDMA_DROP MB Number of megabytes dropped during RDMA transmission to a particular host
HOST_INTERCONNECT Cumulative N_MB_RECEIVED MB Number of megabytes received from a particular host
HOST_INTERCONNECT Cumulative N_MB_RESENT MB Number of megabytes resent to a particular host
HOST_INTERCONNECT Cumulative N_MB_SENT MB Number of megabytes transmitted to a particular host
HOST_INTERCONNECT Cumulative N_RDMA_RETRY_TM ms Latency of the retry actions during RDMA transmission to a particular host
HOST_INTERCONNECT Rate N_MB_DROP_SEC MB/sec Number of megabytes droped during transmission per second to a particular host
HOST_INTERCONNECT Rate N_MB_RDMA_DROP_SEC MB/sec Number of megabytes dropped during RDMA transmission per second to a particular host
HOST_INTERCONNECT Rate N_MB_RECEIVED_SEC MB/sec Number of megabytes per second received from a particular host
HOST_INTERCONNECT Rate N_MB_RESENT_SEC MB/sec Number of megabytes resent per second to a particular host
HOST_INTERCONNECT Rate N_MB_SENT_SEC MB/sec Number of megabytes transmitted per second to a particular host
IORM_CATEGORY Cumulative CT_FC_IO_RQ IO requests Number of IO requests issued by an IORM category to flash cache
IORM_CATEGORY Cumulative CT_FD_IO_RQ_LG IO requests Number of large IO requests issued by an IORM category to flash disks
IORM_CATEGORY Cumulative CT_FD_IO_RQ_SM IO requests Number of small IO requests issued by an IORM category to flash disks
IORM_CATEGORY Cumulative CT_IO_RQ_LG IO requests Number of large IO requests issued by an IORM category to hard disks
IORM_CATEGORY Cumulative CT_IO_RQ_SM IO requests Number of small IO requests issued by an IORM category to hard disks
IORM_CATEGORY Cumulative CT_IO_WT_LG ms IORM wait time for large IO requests issued by an IORM category
IORM_CATEGORY Cumulative CT_IO_WT_SM ms IORM wait time for small IO requests issued by an IORM category
IORM_CATEGORY Instantaneous CT_FC_IO_BY_SEC MB/sec Number of megabytes of I/O per second for this category to flash cache
IORM_CATEGORY Instantaneous CT_FD_IO_BY_SEC MB/sec Number of megabytes of I/O per second for this category to flash disks
IORM_CATEGORY Instantaneous CT_FD_IO_LOAD Number Average I/O load from this category for flash disks
IORM_CATEGORY Instantaneous CT_IO_BY_SEC MB/sec Number of megabytes of I/O per second for this category to hard disks
IORM_CATEGORY Instantaneous CT_IO_LOAD Number Average I/O load from this category for hard disks
IORM_CATEGORY Instantaneous CT_IO_UTIL_LG % Percentage of disk resources utilized by large requests from this category
IORM_CATEGORY Instantaneous CT_IO_UTIL_SM % Percentage of disk resources utilized by small requests from this category
IORM_CATEGORY Rate CT_FC_IO_RQ_SEC IO/sec Number of IO requests issued by an IORM category to flash cache per second
IORM_CATEGORY Rate CT_FD_IO_RQ_LG_SEC IO/sec Number of large IO requests issued by an IORM category to flash disks per second
IORM_CATEGORY Rate CT_FD_IO_RQ_SM_SEC IO/sec Number of small IO requests issued by an IORM category to flash disks per second
IORM_CATEGORY Rate CT_IO_RQ_LG_SEC IO/sec Number of large IO requests issued by an IORM category to hard disks per second
IORM_CATEGORY Rate CT_IO_RQ_SM_SEC IO/sec Number of small IO requests issued by an IORM category to hard disks per second
IORM_CATEGORY Rate CT_IO_WT_LG_RQ ms/request Average IORM wait time per request for large IO requests issued by an IORM category
IORM_CATEGORY Rate CT_IO_WT_SM_RQ ms/request Average IORM wait time per request for small IO requests issued by an IORM category
IORM_CONSUMER_GROUP Cumulative CG_FC_IO_RQ IO requests Number of IO requests issued by a consumer group to flash cache
IORM_CONSUMER_GROUP Cumulative CG_FD_IO_RQ_LG IO requests Number of large IO requests issued by a consumer group to flash disks
IORM_CONSUMER_GROUP Cumulative CG_FD_IO_RQ_SM IO requests Number of small IO requests issued by a consumer group to flash disks
IORM_CONSUMER_GROUP Cumulative CG_IO_RQ_LG IO requests Number of large IO requests issued by a consumer group to hard disks
IORM_CONSUMER_GROUP Cumulative CG_IO_RQ_SM IO requests Number of small IO requests issued by a consumer group to hard disks
IORM_CONSUMER_GROUP Cumulative CG_IO_WT_LG ms IORM wait time for large IO requests issued by a consumer group
IORM_CONSUMER_GROUP Cumulative CG_IO_WT_SM ms IORM wait time for small IO requests issued by a consumer group
IORM_CONSUMER_GROUP Instantaneous CG_FC_IO_BY_SEC MB/sec Number of megabytes of I/O per second for this consumer group to flash cache
IORM_CONSUMER_GROUP Instantaneous CG_FD_IO_BY_SEC MB/sec Number of megabytes of I/O per second for this consumer group to flash disks
IORM_CONSUMER_GROUP Instantaneous CG_FD_IO_LOAD Number Average I/O load from this consumer group for flash disks
IORM_CONSUMER_GROUP Instantaneous CG_IO_BY_SEC MB/sec Number of megabytes of I/O per second for this consumer group to hard disks
IORM_CONSUMER_GROUP Instantaneous CG_IO_LOAD Number Average I/O load from this consumer group for hard disks
IORM_CONSUMER_GROUP Instantaneous CG_IO_UTIL_LG % Percentage of disk resources utilized by large requests from this consumer group
IORM_CONSUMER_GROUP Instantaneous CG_IO_UTIL_SM % Percentage of disk resources utilized by small requests from this consumer group
IORM_CONSUMER_GROUP Rate CG_FC_IO_RQ_SEC IO/sec Number of IO requests issued by a consumer group to flash cache per second
IORM_CONSUMER_GROUP Rate CG_FD_IO_RQ_LG_SEC IO/sec Number of large IO requests issued by a consumer group to flash disks per second
IORM_CONSUMER_GROUP Rate CG_FD_IO_RQ_SM_SEC IO/sec Number of small IO requests issued by a consumer group to flash disks per second
IORM_CONSUMER_GROUP Rate CG_IO_RQ_LG_SEC IO/sec Number of large IO requests issued by a consumer group to hard disks per second
IORM_CONSUMER_GROUP Rate CG_IO_RQ_SM_SEC IO/sec Number of small IO requests issued by a consumer group to hard disks per second
IORM_CONSUMER_GROUP Rate CG_IO_WT_LG_RQ ms/request Average IORM wait time per request for large IO requests issued by a consumer group
IORM_CONSUMER_GROUP Rate CG_IO_WT_SM_RQ ms/request Average IORM wait time per request for small IO requests issued by a consumer group
IORM_DATABASE Cumulative DB_FC_IO_RQ IO requests Number of IO requests issued by a database to flash cache
IORM_DATABASE Cumulative DB_FD_IO_RQ_LG IO requests Number of large IO requests issued by a database to flash disks
IORM_DATABASE Cumulative DB_FD_IO_RQ_SM IO requests Number of small IO requests issued by a database to flash disks
IORM_DATABASE Cumulative DB_FL_IO_BY MB The number of MB written to the Flash Log
IORM_DATABASE Cumulative DB_FL_IO_RQ IO requests The number of I/O requests issued to the Flash Log
IORM_DATABASE Cumulative DB_IO_RQ_LG IO requests Number of large IO requests issued by a database to hard disks
IORM_DATABASE Cumulative DB_IO_RQ_SM IO requests Number of small IO requests issued by a database to hard disks
IORM_DATABASE Cumulative DB_IO_WT_LG ms IORM wait time for large IO requests issued by a database
IORM_DATABASE Cumulative DB_IO_WT_SM ms IORM wait time for small IO requests issued by a database
IORM_DATABASE Instantaneous DB_FC_IO_BY_SEC MB/sec Number of megabytes of I/O per second for this database to flash cache
IORM_DATABASE Instantaneous DB_FD_IO_BY_SEC MB/sec Number of megabytes of I/O per second for this database to flash disks
IORM_DATABASE Instantaneous DB_FD_IO_LOAD Number Average I/O load from this database for flash disks
IORM_DATABASE Instantaneous DB_FL_IO_BY_SEC MB/sec The number of MB written per second to the Flash Log
IORM_DATABASE Instantaneous DB_FL_IO_RQ_SEC IO/sec The number of I/O requests per second issued to the Flash Log
IORM_DATABASE Instantaneous DB_IO_BY_SEC MB/sec Number of megabytes of I/O per second for this database to hard disks
IORM_DATABASE Instantaneous DB_IO_LOAD Number Average I/O load from this database for hard disks
IORM_DATABASE Instantaneous DB_IO_UTIL_LG % Percentage of disk resources utilized by large requests from this database
IORM_DATABASE Instantaneous DB_IO_UTIL_SM % Percentage of disk resources utilized by small requests from this database
IORM_DATABASE Rate DB_FC_IO_RQ_SEC IO/sec Number of IO requests issued by a database to flash cache per second
IORM_DATABASE Rate DB_FD_IO_RQ_LG_SEC IO/sec Number of large IO requests issued by a database to flash disks per second
IORM_DATABASE Rate DB_FD_IO_RQ_SM_SEC IO/sec Number of small IO requests issued by a database to flash disks per second
IORM_DATABASE Rate DB_IO_RQ_LG_SEC IO/sec Number of large IO requests issued by a database to hard disks per second
IORM_DATABASE Rate DB_IO_RQ_SM_SEC IO/sec Number of small IO requests issued by a database to hard disks per second
IORM_DATABASE Rate DB_IO_WT_LG_RQ ms/request Average IORM wait time per request for large IO requests issued by a database
IORM_DATABASE Rate DB_IO_WT_SM_RQ ms/request Average IORM wait time per request for small IO requests issued by a database

     

    信息很丰富,对objectType做下汇总,可以得到存储节点所支持的监控类型:

  • CELL
  • CELL_FILESYSTEM
  • CELLDISK
  • FLASHCACHE
  • FLASHLOG
  • GRIDDISK
  • HOST_INTERCONNECT
  • IORM_CATEGORY
  • IORM_CONSUMER_GROUP
  • IORM_DATABASE
  •     对metricType(指标类型)做下汇总,可以得到指标的不种类型:

        ■ Cumulative: Statistics since the metric was created.

        ■ Instantaneous: Values at the time the metric is collected.

        ■ Rate: Computed value for metric by averaging statistics over a period of time.

        大家接下来关注的另一个问题可能是如何得到这些指标的值。有两种方式:

  • LIST METRICCURRENT,用于显示指标的当前值
  • LIST METRICHISTORY,用于显示指标过去一段时间的历史值
  •     要注意的是,LIST METRICCURRENT不是说CellCLI会帮你发出命令去收集当前指标的值,而只是显示出刚过去一分钟系统所收集到的指标值。下面是一个例子:

        CellCLI> list metriccurrent where name=’CG_IO_UTIL_LG’ and metricObjectName=’DBM.OTHER_GROUPS’ ATTRIBUTES name, collectionTime, objectType, metricObjectName, metricType, metricValue

                 CG_IO_UTIL_LG   2012-05-10T05:01:58-05:00       IORM_CONSUMER_GROUP     DBM.OTHER_GROUPS     Instantaneous   0 %

        CellCLI> list metriccurrent where name=’CG_IO_UTIL_LG’ and metricObjectName=’DBM.OTHER_GROUPS’ ATTRIBUTES name, collectionTime, objectType, metricObjectName, metricType, metricValue

                 CG_IO_UTIL_LG   2012-05-10T05:01:58-05:00       IORM_CONSUMER_GROUP     DBM.OTHER_GROUPS     Instantaneous   0 %

        CellCLI> list metriccurrent where name=’CG_IO_UTIL_LG’ and metricObjectName=’DBM.OTHER_GROUPS’ ATTRIBUTES name, collectionTime, objectType, metricObjectName, metricType, metricValue

                 CG_IO_UTIL_LG   2012-05-10T05:02:58-05:00       IORM_CONSUMER_GROUP     DBM.OTHER_GROUPS     Instantaneous   0 %

        所以,如果你期望当前的某个指标值已经重置或者说清零了,而通过list metriccurrent还能看到非零值,就不是什么奇怪的事情了。

    建议继续学习:

    1. Mysql监控指南    (阅读:19520)
    2. 批量添加主机到cacti+nagios的监控报警系统中    (阅读:13095)
    3. 我常用的主机监控shell脚本    (阅读:11310)
    4. 7 天打造前端性能监控系统    (阅读:9847)
    5. 如何监控HP服务器硬件状态    (阅读:8926)
    6. Cacti 添加 Nginx 监控    (阅读:8730)
    7. Linux下三种常用的流量监控软件对比    (阅读:8502)
    8. Cacti 添加 Memcached 监控    (阅读:7948)
    9. Cacti 添加 Apache 监控    (阅读:7398)
    10. 你应该知道的16个Linux服务器监控命令    (阅读:6697)
    QQ技术交流群:445447336,欢迎加入!
    扫一扫订阅我的微信号:IT技术博客大学习
    © 2009 - 2024 by blogread.cn 微博:@IT技术博客大学习

    京ICP备15002552号-1